JTAG Boundary-Scan Test Tip: Strong Pull-ups on FPGAs

06/30/10

Permalink 05:15:59 pm, by admin Email , 278 words
Categories: JTAG Boundary-Scan, Tips

JTAG Boundary-Scan Test Tip: Strong Pull-ups on FPGAs

Introduction
Many FPGAs in their preconfigured state include relatively strong internal pull-up/pull-downs, often in the 4.7k-ohm range or lower. If a weak pull-up/pull-down resistor is attached to such a pin, there is risk that the pull-up/pull-down test may fail.

Explanation
Consider the simplified diagram below:
 
10k Pull-down attached to a pre-configuration BIDIR FPGA pin
Figure 1: 10k Pull-down attached to a pre-configuration BIDIR FPGA pin

The pre-configuration boundary-scan pin has an effective internal pull-up resistance of 4.7k-ohms. It is externally strapped with a weak 10k-ohm pull-down resistor. Driving the net will not be a problem—when the output buffer is enabled, current will flow through either resistor, allowing the output node to be driven and sensed both HIGH and LOW.

However, the pull-up/pull-down test will tri-state the output of this pin and then expect the 10k pull-down to take the value (as sensed by the input cell) down to “0”. This is not the case—let’s determine why.

Voltage Dividers
When the output buffer tri-states, we end up with a simple voltage divider between the internal effective resistance and the external pull-down. We can calculate the value here:

Vpd = Vcc * Rext/(Rext + Rint) = Vcc * 10k/(4.7k + 10k) ~= 0.7Vcc

This is a very high value and will likely not meet the VIL requirements, causing the resistor test to fail, possibly intermittently.

Resolution

When this situation occurs, the best solution may be to remove the net from testing during the resistor test. While—depending on resistor values—it may be on the border of meeting the threshold requirements and often sense LOW, it is probable that it will not be reliable and cause false test failures. In reality the pull-down should be considered un-testable by boundary-scan pull-up/pull-down test methods.

Leave a comment at our forum >

Media Contact: Ryan Jones

Search

RSS Feed - Latest Posts

This site features posts from the Corelis Support and Engineering team for the purpose of helping to educate other engineers and students alike about Boundary-Scan technology, testing, and maximizing productivity.

XML Feeds

May 2012
Sun Mon Tue Wed Thu Fri Sat
 << <   > >>
    1 2 3 4 5
6 7 8 9 10 11 12
13 14 15 16 17 18 19
20 21 22 23 24 25 26
27 28 29 30 31    
Online Marketing BlogCatalog Globe of Blogs Bloggapedia, Blog Directory - Find It! Blog Listings