What’s New in ScanExpress 9.12.0

ScanExpress Application Versions

ApplicationVersion
ScanExpress Debugger6.14.0
ScanExpress DFT Analyzer2.16.0
ScanExpress Flash Generator3.20.0
ScanExpress Programmer1.29.0
ScanExpress Runner6.33.0
ScanExpress Runner Gang4.64.0
ScanExpress TPG/Merge/JET2.28.0
ScanExpress Viewer2.17.0

Bug Fixes and Improvements

ScanExpress version 9.12.0 is a maintenance release with improvements focused on ScanExpress JET, ScanExpress TPG, and ScanExpress Runner. This includes improved IDCODE & USERCODE test reports, FlexNet licensing for ScanExpress Runner Gang Edition, and more. Customers with a current support contract are welcome to upgrade for the latest bug fixes and improvements.

ScanExpress JET CPU Support & Improvements

ScanExpress JET Zynq-7000 now includes additional peripheral tests and advanced memory diagnostics support. Tests for Ethernet loopback, eMMC flash in-system-programming and I2C discovery add additional test coverage, which the new advanced memory diagnostics translate memory test results to pin- and net-level diagnostics. Please contact Corelis Sales for pricing and availability.

ScanExpress Release Notes

ScanExpress Debugger (v6.14.0)

  • SED-27: Resolved potential out-of-memory crash during script execution when calling scan_update()in a loop.

ScanExpress JET (v2.28.0)

  • SEJET-147: Added Xilinx Zynq-7000 ethernet loopback test.
  • SEJET-238: Added Xilinx Zynq-7000 eMMC flash support.
  • SEJET-239: Added Xilinx Zynq-7000 I2C discovery test.
  • SEJET-242: Added Xilinx Zynq-7000 advanced memory diagnostics support.
  • SEJET-220: Fixed an issue where the TCK rate setting was not being saved when using an Embedded USB2JTAG controller.
  • SEJET-241: Fixed an issue with the load_bsdl() scripting function when parsing certain BSDL files.
  • SEJET-245: Fixed an advanced memory diagnostics issue where changing the DDR data width limits the logical address range tested.

ScanExpress Runner (v6.33.0)

  • SER-520: Added an optional timeout for the User Message test step option.
  • SER-134: Removed extraneous “leading pattern” output from the BSR length portion of infrastructure test results.
  • SER-65: Corrected display of actual sampled USERCODE values in passing infrastructure test results.

Runner Gang (v4.64.0)

  • SERG-36: Added support for ScanExpress Runner Gang FlexNet licensing.
  • SER-520: Added optional timeout for User Message test step option.
  • SER-134: Removed extraneous “leading pattern” output from the BSR length portion of Infrastructure test results.
  • SER-65: Corrected display of actual sampled USERCODE values in Infrastructure test results.

ScanExpress TPG (v2.28.0)

  • SEBT-305: Resolved an ODB++ netlist conversion issue with some files would produce an “Encountered an improper argument” error message.
  • SETPG-259: Resolved potential controller issues when a ScanExpress TPG script terminates after having called io_i2c_begin() or io_spi_begin() without calling the corresponding io_i2c_end() or io_spi_end()

ScanExpress Viewer (v2.17.0)

  • SEBT-305: Resolved an ODB++ netlist conversion issue with some files would produce an “Encountered an improper argument” error message.